How to Model Colored and Tristimulus Sources


This article describes the various models available in non-sequential mode for defining broadband sources. These models fall into two categories: (1) source definitions based on measured spectra and (2) source definitions based on Tristimulus values.

Authored By: Sanjay Gangadhara

Introduction
A number of optical systems (e.g. digital displays and projection systems) require knowledge of the photometric (human eye) response of the system to a broadband source. In Zemax, a polychromatic source may be defined either by using multiple system wavelengths or by defining the Tristimulus (or associated) values for the source. The resultant color distribution of the output image may be visualized using the Detector Color object, as described in the article entitled “How to Measure and Optimize Color Data”. A brief overview of the various source models available in non-sequential mode is provided in this article.


Source modeling using measured spectra

There are a number of ways to model polychromatic sources in the non-sequential mode of Zemax. The default is to define multiple system wavelengths and weights in the Wavelength Data dialog box:

Defining system wavelengths and weights

and then set the “Wavenumber” parameter value to 0 for the associated source object:

How to define a polychromatic source using system wavelengths

This method allows up to 24 different wavelengths to be defined for the source, each with a (potentially) different value for the relative weight. There may be situations, however, in which you wish to model multiple sources in the system, each with a different spectral distribution. Or perhaps you wish to model a single source that is composed of more than 24 wavelengths, and you don’t want to use multiple configurations to do so.  These issues can be addressed by selecting for each source object something other than System Wavelengths for the Source Color option. The Source Color option is found in the Sources Tab of the Object Properties dialog box:

Options for defining source spectrum

A number of options are available for defining the spectral distribution of each source in a system, and a discussion of those options associated with Tristimulus source models will be provided in the next section. To define a source based on a measured spectrum, there are three options available (in addition to System Wavelengths):

• Uniform Power Spectrum: The relative intensities are equal for all wavelengths defined
• Black Body Spectrum: The relative intensities are determined from the blackbody emission curve at a particular temperature for all wavelengths defined
• User Defined Spectrum: The relative intensities are given in a text file for all wavelengths defined

For the case of a User Defined spectrum, both the wavelength and corresponding relative intensity values are provided in a text file (more details are provided in the section entitled “Defining a spectrum file” located in the chapter of the Zemax manual entitled “Non-Sequential Components”). This allows users to explicitly provide measurement data for a source directly to Zemax. Up to 100 data points may be provided in the file.

For the Uniform Power Spectrum and Black Body Spectrum, the wavelengths that will be used to model the source are defined in the dialog box:

Specifying wavelengths used for spectra not defined by system wavelengths

The wavelength spectrum is uniformly spaced, going from the initial to the final wavelength values specified in the number of steps given by the “Spectrum” parameter. For example, in the above system the wavelengths used to model the Black Body source are 0.44, 0.54, and 0.64 microns (i.e. from 0.44 to 0.64 microns in 3 steps), and the relative weights for each of these three wavelengths are determined by the blackbody emission curve at a temperature of 10,000 Kelvin.

The manner in which wavelengths are used to define the source is the same for the Tristimulus source models as it is for the Uniform Power and Black Body source models. As we will see in the next section, information in the Prescription Data Report is available to determine the wavelength weights for all source models other than System Wavelengths.

The flexibility of the User Defined Spectrum allows definition of an arbitrary source composed of up to 100 wavelengths. However, in many cases the information provided for a source is not the measured spectra, but rather a Tristimulus characterization of the source. This information may also be used to model a source in non-sequential mode, as described next.



Source modeling using Tristimulus data

An overview of Tristimulus source modeling is provided in the following Wikipedia article: http://en.wikipedia.org/wiki/CIE_1931. As described in that article, the Tristimulus XYZ values characterize the color of a source as seen by the human eye:

The human eye response, as characterized by the 1931 CIE Standard Observer model

Calculation of the Tristimulus XYZ values from the human eye response

The quantities x-bar(l), y-bar(l), and z-bar(l) represent the human eye response, while I(l) represents the spectral distribution of the source.

Since the Tristimulus values represent the integral of the spectral distribution over the human eye response, many different distributions can generate the same XYZ values. In other words, different spectra can generate the same color. Thus, in addition to specifying XYZ values for the source, in Zemax we must also specify the wavelengths associated with the source distribution. This is done in the same manner as it was done for the Uniform Power and Black Body source models, as described in the previous section.

To choose the Tristimulus XYZ model for a particular source object, select the “CIE 1931 Tristimulus XYZ” option under the Source Color setting in the Sources Tab of the Object Properties dialog box:

Defining the source spectrum by the Tristimulus XYZ values

Once this model has been selected, options to define the XYZ and the wavelength values for the source are shown. In the above example, the wavelengths used to model the source are 0.44, 0.54, and 0.64 microns (i.e. from 0.44 to 0.64 microns in 3 steps), and the Tristimulus values for the source are X = 1, Y = 0.5, and Z = 0.25.

Once the XYZ and the wavelength values are defined, Zemax performs a fitting to determine the relative intensity of light at each wavelength. The intensity values are chosen to generate the desired XYZ values, and in such a way as to keep the RMS of the intensity values at a minimum while ensuring that none of the wavelength weights are negative. The fit results are shown below the input data, along with a color bar showing the closest RGB representation for this fit.

In the above example, an exact match to the input XYZ values has been generated. When an exact match is not found, it is generally because the wavelength spectrum does not include enough wavelengths and/or the correct wavelengths to model the color of interest, or because the input XYZ values do not represent a color that can actually be seen by the human eye. More details are provided in the above Wikipedia article (e.g. see the chromaticity diagram), as well as in the section entitled “The spectrum fitting algorithm” located in the chapter of the Zemax manual entitled “Non-Sequential Components”.

Values for the intensity distribution may be observed in the Prescription Data Report:

Accessing the Tristimulus calculation data in the Prescription Data Report

Summary of the Tristimulus fitting results shown in the Prescription Data Report

In this report, we see the three wavelengths used to model the source listed in the first column, and the x-bar, y-bar, and z-bar values (i.e. the human eye response) for each wavelength listed in columns 3-5. The relative intensity (weight) for each wavelength is listed in column 2. The weights are normalized so that the total sum is unity, and the weights are always provided in terms of Watts. For example, if a source with the above chromatic characteristics launched 1 W of power, ~ 0.061 W of light would be radiated at 0.44 microns, ~ 0.064 W of light would be radiated at 0.54 microns, and ~ 0.875 W of light would be radiated at 0.64 microns.

The last column in the report shows how many Lumens would be seen at each wavelength for the given weightings. The number of Lumens is simply the product of the weight and the y-bar value (as described in the Wikipedia article), multiplied by 683. This final scale factor corresponds to the number of Lumens for 1 Watt of light at 0.555 microns, for which the y-bar value is 1.0. Thus, for the wavelengths shown above:

0.44 microns: 0.061*0.023*683 = 0.9585 Lumens/Watt
0.54 microns: 0.064*0.954*683 = 41.921 Lumens/Watt
0.64 microns: 0.875*0.175*683 = 104.54 Lumens/Watt

If this source launched 1 W of power, the human eye would see ~ 147.4 Lumens (= sum over all wavelengths). It is interesting to note that although the relative intensity in Watts for light at 0.54 microns is small for this source, the number of Lumens contributed at this wavelength is significant, because of the large y-bar value. In other words, the human eye is very responsive to the green portion of the wavelength spectrum.

As indicated above, the relative intensity listed in the Prescription Data Report is always in Watts, as rays are always traced in terms of Watts. If the source is defined in terms of Lumens (which can be done by changing the Source Units to Lumens under the Units tab of the General dialog box), Zemax will first convert the source to the equivalent number of Watts, using the Lumens/Watts conversion shown above. Once the source power in Watts is determined, the distribution at each wavelength is known from the relative weights. Once a ray of a particular wavelength hits a detector, its intensity may be converted back to Lumens, if the Detector Color object is used (see the article entitled “How to Measure and Optimize Color Data”).

Zemax supports other source definitions which are equivalent to the Tristimulus XYZ definition. These are:

• Chromaticity xy (defined in the same Wikipedia article as XYZ)
• RGB (defined by the following Wikipedia article: http://en.wikipedia.org/wiki/Srgb)
• D65 White (XYZ values corresponding to the white color on computer monitors: http://en.wikipedia.org/wiki/D65)
• Color Temperature (XYZ values that generate the same color as a blackbody at a particular temperature)
• Chromaticity u’v’ (defined by the following Wikipedia article: http://en.wikipedia.org/wiki/CIELUV_color_space)

In all of the above cases, Zemax converts the input data into Tristimulus XYZ values. The same fitting algorithms are then used to determine the intensity distribution for the source over the inputted wavelength range.

As described in the previous section, there are also sources in Zemax which require no fitting:

• System Wavelengths (relative intensities and wavelengths defined in Wavelength Data dialog box)
• Uniform power (relative intensities are equal over all wavelengths)
• Black Body (relative intensities determined from true blackbody curve)
• User Defined (relative intensities and wavelengths given in a text file)

These sources may or may not generate an output that can be seen by the human eye, as a result. Nonetheless, in all of these cases – except for System Wavelengths – the relative weightings and associated x-bar, y-bar, and z-bar values will be shown in the Prescription Data Report.

When System Wavelengths is chosen, then the wavelengths defined in the Wavelength Data dialog box are used for the source (default). In this case, the relative intensities are not provided in the Prescription Data Report, but they are of course listed in the Wavelength Data dialog box. If the source units are in Lumens, then the weights provided in the Wavelength Data dialog box are also in Lumens; this is the only time in which wavelength weights are not given in Watts.



Summary
The spectral distribution of sources in Zemax may be modeled using either measured data, Tristimulus data, or both. In addition, multiple sources in a system can have different definitions. For example, one source can use system wavelength, while another could use XYZ values, and a third could use a User Defined spectrum. Thus, there is great flexibility in source modeling in the non-sequential mode of Zemax.